Under the theme of the double -carbon era, is the cold board cooling really in the air tower?

Author:Beauty has their own wonderful Time:2022.09.27

It is the consensus of the current human society through the "Carbon Dafeng" and "Carbon neutralization" operations. Entering the digital age, as a physical carrier running as an information system, the scale and number of data center construction are growing rapidly. While continuously providing the economy and society with essential computing power, it is necessary to assume the heavy responsibility of energy conservation and emission reduction and green development. Essence

Among the many green data centers solutions, the technological innovation of the cooling system is the most significant and the most important development direction in the industry. Well -known chip manufacturers Intel recently jointly released the "Green Data Center Innovation Practice -Design Reference of Cold Board Cold System" to strengthen the industry's awareness of cold -board liquid cooling and promote the green development of the data center industry process.

Ecological United to promote green data center transformation

In recent years, my country's data center has grown rapidly, accounting for about 1.5% -2% of the total power consumption of the whole society. In view of this, the state introduced a series of policy guidance of the green development of data centers, and proposed a hard indicator for data center power utilization efficiency (PUE) The PUE index in the national hub node of the "East Digital West Calculation" is required to be controlled within 1.25.

The construction of Green Data Center is a complex system project. In addition to the energy utilization efficiency indicator of PUE, it also involves a variety of factors such as green design and green procurement, energy resource management management, and equipment green management. Therefore The collaboration of innovative technologies and schemes and comprehensive treatment.

As a practitioner of sustainable development concept, and leading enterprises in the semiconductor industry, Interea explores the energy -saving and emission reduction technology, tools and methods of green data centers, focusing on energy efficiency and power density, advanced heat dissipation technology and infrastructure intelligence These three vertical fields, from the level of XPU and other devices to the four levels of server systems, racks and data centers, innovate the launch of the "four horizontal and three vertical" matrix green data center technology frameworks (see Figure 1) to accelerate the data center industry Energy -saving carbon reduction provides flexible combination and customized solutions.

▲ Tuyi Intel Green Data Center Technical Framework

In the daily operation of the data center, the cooling system has always been the main source of the energy consumption of non -IT equipment. The energy consumption of traditional air -cooled systems can often be close to half of the overall energy consumption of the data center. At the same time, with the development of high secrets and large -scale development, traditional cooling technology has difficulty meeting the heat dissipation needs of new data centers.

Therefore, more advanced refrigeration technology has become one of the core points of the construction of green data centers. The new data center refrigeration technology represented by cold plate -type liquid cooling, with higher cooling efficiency, can support higher power density and low requirements for data center computer room renovation, which has become the highest development direction in the industry.

As a technique of stronger cold and cold heat dissipation capabilities, it can be used in data centers to show the following obvious advantages:

Meet the heat dissipation needs of high -power density cabinets, and improve data center use efficiency;

The circulatory system consumes less energy, and the system noise is small;

The area is small, easy to choose, and the national layout can achieve low PUE operation;

Reduce total cost and increase computing power output;

The residual heat recovery is easy to achieve, the heat source taste and the remaining heat system are high;

Strong adaptability can be directly compatible with the original refrigeration system.

"Green Data Center Innovation Practice -Design Reference of Cold Board Cold System". Many partners, including CSP, operators, corporate users, OEMs, liquid cold components, and server custodians, have participated in the compilation. Intel and one of the important achievements of the industrial ecological partners closely cooperated and joint innovation, they aimed at the purpose Share the consideration of the design selection of key components of the cold plate liquid cooling technology with the cold plate -cooling ecological partners and potential users, and promote the standardized development of the cold plate liquid cooling system, thereby reducing design and use costs, promoting the establishment and improving cold board Solid cold ecosystem.

Professional, detailed, and landing solution cold practice reference book

From a professional perspective, the design reference of "Green Data Center Innovation Practice -Cold Plate System Design" has elaborated the concept, principles, and composition of the cold plate -type liquid cooling, and according to the needs of the actual application scenarios, how to solve how to calculate how to solve the solution The scheme and the chilled cold plate cooling accessories give a highly feasible reference suggestion.

Cold plate -type liquid cooling refers to the use of liquid as a heat transfer working quality in the inner flow channel of the cold plate, and the non -contact liquid cooling technology that cools the heat source to cool the heat source through heat transfer. In the cold plate -type liquid cooling system, the server chip and other heat devices do not directly contact the liquid, but to dissipate the cold plates that assembled on the electronic component that needed cooling. Therefore, this method has a small modification of the existing server chip components and affiliated components, and has a stronger operability. It has become the highest maturity and the most widely used liquid cooling solution.

"Green Data Center Innovation Practice -Design Reference of Cold Board and Cold Systems" revolves around the design of the entire link of the first side and the secondary side of the liquid cooling (see Figure 2), which can participate in the design, verification, pipeline pipelines participating in the cold plate heat dissipation system The engineering practice of connection assembly, system detection and maintenance personnel provides systematic reference and guidance.

▲ Figure two cold plate -type liquid cooling overall link map

Among them, the cold source of the cold -board liquid can use a mechanical refrigeration system and a natural cooling system. The mechanical refrigeration system includes the air-cooled and cold water system and the water cooling water system, which can provide a medium temperature frozen water at 12C-18 ° C. Natural cooling is the use of the cold amount of outdoor air without mechanical refrigeration without mechanical refrigeration when the outdoor meteorological conditions permitted. In the cooling process, the natural cooling system can be achieved using an open cooling tower, closed cooling tower and dry cold device, which can provide cooling water of more than 30C. The form of liquid cold source must be determined in conjunction with secondary end -end water temperature requirements and the outdoor environment of the project. The secondary liquid circuit refers to the design from the cold volume distribution unit to the rack, connecting the cooling industrial quality manifold to the IT device, and then returning the design of the cold volume distribution unit through the meter. The calories from the secondary cooling circuit are passed to the plate heat exchanger through the cooling volume to distribute the unit to the first -side cooling circuit, which is eventually discharged into the atmosphere or was recovered by the heat.

The design considerations of the cold plate system involve cooling work, cold board design, cold volume allocation unit (CDU), rack -type cooling work quality supply rebate, circulating pump, self -sealing fast -changing joint, secondary side pipeline path , Backboard air conditioning and other extensive content areas and design standards and specifications. The design reference has given the above elements systematically.

Design considerations from the perspectives of hardware and efficiency. In terms of hardware, the design refers to the detailed explanation of various components and materials, analyzes the advantages and disadvantages of different selection types, discusses the structure, design and other issues that may be involved in components and materials. The national standards and terms that the materials should be followed are recommended to the current product types that can be adopted.

In terms of efficiency, the design reference is based on the actual scene, and the role of each component and the effectiveness that should be achieved, especially in different parameters, structures, and use environments. Each product should be volume, weight, efficiency, and even transportation links. The performance indicators reached.

The stable service and uninterrupted service are the core demands in the data center operation. The design refers to the leak detection and intervention of the cold plate -type cooling system, and the stress security regulation sets a single chapter explanation to ensure the safe and stable operation of the data center when using the cold plate -type cooling technology.

Create a new green ecosystem and open the new future of liquid

In the same period when the "Reference of the Green Data Center Innovation Practice -Design of Cold Board and Cold System", Intel joined hands with a wide range of ecological partners to set up the "Green Data Center Technology Innovation Forum" to gather upstream and downstream manufacturers of ICT industry "Handprint", jointly build a green, sustainable industrial ecology.

The release of "Green Data Center Innovation Practice -Design of Cold Board Cold Systems" provides a reliable path for the popularization of data center cold plate -type liquid cooling technology, laying the foundation for the application of liquid cooling technology and research. As the data center enters the age of liquid cold, the green computing power will become the most important driving force and guarantee for the national economy to achieve high -quality development, laying solid cornerstone for the overall "carbon neutralization" of the digital economy, and contribute to the global sustainable development.

| Article Source: China IDC Circle

- END -