[Fire Host Disposal During] These units are named!

Author:Yichang Firefigh Time:2022.09.03

To further purify the fire safety environment

Continue deepening fire safety inspection operation

Give full play to the role of media and social supervision

Promote rectification of fire hazards

Yichang Fire Rescue Division

Now exposed a group of fire hidden dangers

The fire hazards are requested to rectify the rectification within the time limit

Ensure fire safety

The specific list is as follows:

Hidden danger unit:

Wufeng Tujia Autonomous County Zhouzheng private house dishes

There are fire hazards:

1. The number of fire extinguishers is insufficient;

2. The electrical line is not protected.

Hidden danger unit:

Hubei Jinshan Commercial City Co., Ltd.

There are fire hazards:

1. During the inspection, the fire control room is only one person on duty (holding the certificate), on -site operation and testing, the business is not skilled;

2. Only three people on duty in the fire control room hold the certificate, and the number of licenses is insufficient;

3. There is no high and low water level alarm display device in the consumer control room;

4. The automatic power supply controller's backup power supply failure of the fire control room fails, and many fire alarms and failures have not been checked and eliminated in time;

5. Self -inspection testing, spray pump, and individual ventilation of the remote launch test of the fire controller of the consumer control room have no response;

6. The fire pump control cabinet of the fire pump room is in a manual state;

7. Fire pump rooms are not set up on a local water level display device;

8. Spray pump testing of fire pump rooms, no response is launched manually;

9. The water storage water tank is 18 cubic meters, and the effective volume is insufficient;

10. The regulatory pump is set in a manual state, and the pipe network is not supplemented in time;

11. The unit's fire protection water pipe network leaks seriously and urgently needs maintenance;

12. Spring check -in at the front room of the 20th floor of the business hotel, the manual test is not responding;

13. Spring inspection of the front room of the 20th floor of the business restaurant, the fire door has no closed doors and sequencers;

14. Spring check -in squares, a fire -resistant rolling curtain is not set up and landing and landing device, and no manual hinge cannot be controlled on the spot;

15. Underground negative layers of cultural squares and part of the connected area of ​​the garage have not been effectively refined;

16. Some shops in the cultural square change their uses without authorization, and actually use it in the warehouse;

17. The signs of multiple fire evacuation indicators are not bright;

18. A few leased personnel illegally stay in the market at night;

19. Electrical lines and part of the gas pipelines have not been carried out on a regular basis without related records;

20. The unit's automatic fire protection facilities have not carried out relevant testing for three consecutive years;

21. Daily fire inspections are not carried out as required, and the implementation of fire safety management needs to be strengthened.

Hidden danger unit:

Gaoqiao Township Welfare Institute in Xingshan County

There are fire hazards:

1. Only one person on duty in the fire control room holds a certificate and does not meet the requirements of the control room;

2. No test report on fixed fire protection facilities in the past two years;

3. The front chamber of the fire elevator of the Kangyanglou Building is closed, and the stairwell setting does not meet the requirements of the specifications.

Hidden danger unit:

Yichang Weihan Auto Service Co., Ltd.

There are fire hazards:

1. The safety export logo of the exhibition hall is damaged;

2. There is a failure in the fire control cabinet;

3. Settings of the repair workshop do not meet the requirements.

Hidden danger unit:

Yichang Lincheng Renewal Resource Co., Ltd.

There are fire hazards:

Use the foam clip core color steel plate to build a dormitory.

Hidden danger unit:

Xinlong Express Hotel

There are fire hazards:

Fire door closed doors were demolished.

Hidden danger unit:

Jiahe Home District

There are fire hazards:

1, No. 21 extension shielding point;

2. The control room staff will not operate.

Hidden danger unit:

Guigui Sanfeng Culture Communication Co., Ltd.

There are fire hazards:

1. There is a lack of a evacuation staircase on the three floors;

2. There is a shielding information on the control cabinet of the automatic alarm system;

3. The hydraulic alarm bell does not ring at the time of testing;

4. Insufficient pressure of seven fluoropropane devices;

5. Fire door identification is that handwriting does not meet the requirements;

6. The automatic fire protection facilities have not been tested in the year.

Hidden danger unit:

Hubei Guangchen Pharmaceutical Co., Ltd.

There are fire hazards:

1. There is no signal of the automatic fire alarm system on the No. 2 workshop, and there are multiple communication faults on the host;

2. Pump rooms and fire pools are being transformed waterless, and the pipe network pressure is insufficient;

3. Graphics show that electrical fire monitoring is suspended, and there is no district logo on the broadcasting tray.

Hidden danger unit:

Wufeng Tujia Autonomous County Good Noodle Restaurant

There are fire hazards:

1. The number of fire extinguishers is insufficient;

2. Employees do not use fire extinguishers.

Hidden danger unit:

Jiajiafu Life Supermarket, Yuan'an County

There are fire hazards:

1. Mixed objects in the staircase to occupy safe exports;

2. Exit B -level fire door closed doors closed;

3. Daily inspections are not carried out.

Hidden danger unit:

Dangyang Hedien Gas Co., Ltd.

There are fire hazards:

1. In the explosion -proof area, the electrical line equipment is not explosion -proof;

2. Some gas cylinders are not consistent with the name of the logo;

3. The storage area is stacked with debris and is not cleaned up;

4. The vehicle does not wear a fire cover in the explosion -proof area.

Hidden danger unit:

Xingshan County Xingfa Property Management Co., Ltd. (Huaweiyuan Community)

There are fire hazards:

1. Set up a closed evacuation channel for the fence door in the stairwell;

2. The indoor fire hydrants are not kept intact and effective, and the equipment is missing;

3. Packing combustible waste supplies in the staircase.

Hidden danger unit:

Yichang Lexin Property Co., Ltd. Cultural Plaza

There are fire hazards:

1. There are 248 faults in the fire control cabinet; 2. The fire hydrant pump cannot be set to an automatic state;

3. The setting of the fire control room does not meet the standard and cannot be directly connected to the outdoor;

4. Fire facilities are not detected;

5. Control cabinet printer has no paper;

6. The alarm system is basically paralyzed.

Hidden danger unit:

Fengchen Building, Yujie Property Management Co., Ltd.

There are fire hazards:

1. Fire automatic alarm system has no failure;

2. Partial evacuation indicator is damaged, and the fire automatic alarm system has failed, and some detectors are suspended;

3. Some indoor fire hydrants are blocked.

Hidden danger unit:

Wang Berlin Yufu

There are fire hazards:

1. Backlessly stacked by staircases;

2. A safe export sign is not kept intact and effective.

Hidden danger unit:

Dianjun area Qianjin Pharmacy

There are fire hazards:

1. No safety export signs;

2. The emergency lighting light is discontinued and demolished;

3. Some electrical lines are not laid.

If you find you

There are fire hazards and fire safety violations

Please pick up the phone in your hand and dial

"12345"

Fire is fierce in the tiger

Precautions

Yichang Fire reminds you

Follow the fire safety around you

Work together to create a peaceful society

- END -

Linyou Procuratorate carried out the "monthly lecture" mentioned ability activity

After listening to this vivid lecture, I deepened my understanding of the procuratorate and increased my awe of the law ... This is the new this year Recruiting secretary Feng Hao's speech.Since 202...

The Municipal Urban Management and Law Enforcement Bureau exposed the recent "three types of pl

In response to the recent epidemic prevention and control situation and the latest...