The millisecond response failure, this power "airbag" is very special
Author:State Grid Time:2022.06.24
June this year
It is the 21st National Safety Monthly
Resolutely keep the big power grid security lifeline
It is the top priority of power grid companies
in daily life
If a household high -power electrical appliance fails
Generally triggers the switch jumper
Prevent accidents
This is fault protection
In fact, fault protection exists in the power system
every session
The stream station is an important part of it
today
Take everyone to dissect "a sparrow"
Take a look
Baihe Beach-Jiangsu ± 800 kV high pressure
DC transmission engineering stream station
If a failure occurs
How should power people guarantee the security of the power grid?
△ Yucheng changed stations.
Yucheng Streaming Station is Baihe Beach-Jiangsu ± 800 KV high-voltage DC transmission project
Site to Jiangsu
Yucheng changed station uses the world's first first
Conventional DC and Flexible DC hybrids
As the last safety defense line of the project
Fault protection is the top priority
What are the problems currently facing the fault protection of the stream station?
Yucheng changed the stations, and bears the heavy responsibility of converting DC electricity from Sichuan to AC power, and then sent to thousands of households in Jiangsu.
For conventional stations, the DC system voltage is affected by the voltage of the AC system. Once the AC system fails, the DC system will not be able to run normally.
After the Yucheng replacement station adopts conventional DC and flexible DC hybrid technology, the DC system voltage is not affected by the voltage of the AC system. Once the AC system fails, the DC system can continue to transport. However, the excess energy generated by the DC system will cause damage to other key equipment.
If the DC system is suspended, although it can ensure safety, once the failure is eliminated, the DC system will take a few days to affect reliable power supply.
Then, is there a fault protection measure
When the communication system fails
It can protect the key equipment and not damaged
Can it not affect the normal operation of the DC system?
The electric man thought of — airbags!
Well known
When a car collides
The airbags can play for drivers and passengers
Key protection
△ Automotive airbag played (picture source network
In order to keep the DC system without stopping
Protection of failure
Engineering and technical personnel developed and applied
Electricity "airbag" -
The world's first ± 400 kV DC can control
Self -recovery Energy Device
△ The world's first ± 400 kV DC can control the self -recovery and eliminate energy
Just like the car suffers from a certain collision
The airbag will be inflated quickly
Absorb the inertial impact of the driver
So as to reduce the damage of personnel
Change stream station in Yucheng
When the communication system fails
Electricity "airbags" will respond in milliseconds
Absorb the excess energy generated by the DC system
Prevent core devices such as streaming valves and other core devices are damaged due to excessive voltage
After removal of the recovery of the communication system failure
The time consumed by the DC system restart
△ Yucheng changed stations.
However, different from
The softness of the airbag
The electric version "airbag" is a one
"Steel tough guy"
It is a large -capacity lightning weapon, ultra -high -speed trigger gap switch,
Ultra -high -speed crystal tube electronic switch,
Advanced equipment such as fast mechanical switch
△ Lightning mock tower.
The lightning absorber is the key component of this power "airbag"
The tower of about 14 meters high
Each layer is composed of 136 lightning arresters
A total of 5 layers of 680
Two sets of anti -energy devices have a total of 1360 lightning offers
With this series of hardcore equipment
Failure protection is naturally reliable
Its failure response is less than 1 millisecond
The absorption energy can reach 300 mega focus or more
Before this behemoth goes to work
Whether it already has a normal working state
"Physical Examination" before post
To prevent the lightning mock tower
Damage occurs during transportation installation
June 17th
State Grid Jiangsu Academy of Electric Sciences completed two sets
The world's first ± 400 kV DC can control self -recovery and consumer energy device
Lightning -resistor group high -voltage test
At this point, the two sets have the condition of "on -the -job" condition
What is a high -pressure test?
"Reference voltage" and "leakage current" are the two key indicators of signs of the health state.
The high -voltage test of the lightning offer is to compare the leakage current under the test measured DC reference voltage and 0.75 times reference voltage, compare with the national standard value, and determine whether the missionarrant is qualified.
Use traditional test equipment for lightning offers
Perform high -pressure test
Only about 13 can be completed every day
According to this calculation, at least 3 months of consecutive tests need to be tested for 3 months
In order to complete the test work of 1360 lightning arresters
This obviously cannot keep up with the progress of engineering construction
Develop a new test equipment and carry out the entire group of minefield tests
The top priority for becoming a power researcher
△ Part of the structure of the emperor energy device of Yucheng replacement station.
State Grid Jiangsu Academy of Electric Sciences proposed
Multi -column parallel DC high -pressure generator overall pressure test method
In this way
You can test the 136 lightning arresters per layer at the same time
All minefarers can be completed within 1 week
△ Professionals are doing test preparation.
State Grid Jiangsu Academy of Electric Sciences Joint relevant units
Innovative development
DC test integrated equipment
And measurement and control unit
Solved the uneven diversion of the multi -column mineslinkler under pressure
technical challenge
How to conduct high -pressure tests?
Professionals installed 136 measurement and control units on each layer of low -voltage end, and then connected the measurement and control unit in parallel and grounding. Each layer of the high -pressure end of the minefarers formed a test point, which was tested by connecting the DC high -pressure generator through the wire connection.△ Professionals install and control the measurement and control unit for the lightning offer.
The test personnel received and returned the data collected by the test control unit through the wireless transmission device to determine whether the lightning weapon was qualified.
△ High -pressure test scene.
When the two minefield tower completes the "physical examination"
After connecting with other components through the wire
Electricity "airbag" is about to be officially "entered"
Under the careful care of the power man
Electricity "airbag"
It will effectively guarantee clean hydropower from Sichuan
It is constantly developing for Jiangsu's high -quality development
Inject surging kinetic energy
- END -
Chongqing released the first batch of smart city application scenarios to open a list of 20 projects in the opening list
Cover reporter Cao Yu YuyanOn June 23, the cover news was learned from the press c...
Viewing data value Enlightenment Digital Digital Future "The Power of Digitalization" is released
On June 20, the digital insights of the founder of Shenzhou Digimon Guo Wei's Digi...